• en
  • es
  • fr
  • de
  • Request a quote ↗
    kesense. Request a quote
    7050B Portable Pressure Flow Calibrator product illustration
    7050B

    Portable Pressure Flow Calibrator

    Request a Quote
    Every specification carries its measurement conditions — range, ambient temperature, compensation mode, gas and response time. We do not publish a bare accuracy figure without the context that makes it meaningful.

    Overview

    A measurement chain without a verifiable calibration trail cannot support a compliance report, and an instrument that cannot be verified on site will eventually stop a test programme. kesense manufactures the reference instruments that make your measurements traceable: flow calibrators, gas mixing systems, high-precision combined calibrators, weighing systems and odorimetry instruments.

    Key specifications — 7050B

    Parameter Specification
    Model 7050B
    Product type Portable Pressure Flow Calibrator
    Flow rate Flow (5~150) L/min
    Pressure range Pressure (0~2500) Pa, (-2500~+2500) Pa
    Temperature sensor (PT100) PT100 calibration 0/44/80/120/199/200/300/400C
    Optional flow ranges Optional (10~500) mL/min and (0.5~100) mL/min
    Weight ~6.0 kg
    Dimensions (W×D×H) 303x277x312 mm

    Measurement conditions

    • Reference temperature — 25 °C ambient unless a row states otherwise
    • Reference pressure — 101.3 kPa
    • Humidity — non-condensing
    • Response time — T90 as stated per configuration

    Range, compensation mode, gas and response time are confirmed per configuration at order. Every figure above is tied to its stated condition — ask us for the exact reference behind any number.

    Standards

    JJG 586-2006 · JJG 633-2005 · JJG 680-2021 · JJG 875-2019

    Applications

    Laboratory accreditation and ISO/IEC 17025 preparation · instrument verification before and after field campaigns · analyser calibration for stack and ambient monitoring · reference gas preparation · filter weighing in gravimetric analysis · odour measurement per EN 13725

    Configuration

    Measurement range, sampling flow, probe type, gas configuration, output protocol and data storage are specified at order. State your requirement and we will confirm the configuration in the quotation.

    Frequently asked questions

    Which calibration instrument do I need?

    Match it to what you calibrate and how much flow you need. The 7020A at up to 1500 L/min covers stack samplers. The 7030 soap film meter covers the low-flow analysers. The 7050B and 8040 cover low, small, medium and large flow ranges plus pressure and PT100 temperature points in one instrument. If you calibrate gravimetric filters, the 8061B constant temperature and humidity weighing system is the relevant unit. Tell us your instrument list and duty cycle and we will specify the smallest system that covers it.

    Why does calibration traceability matter so much?

    Because the report, not the instrument, is what a regulator accepts. Your accredited test body needs a measurement chain that can be traced back to national standards through documented, repeatable verification. A calibration certificate from an untraceable source breaks that chain and can invalidate results that were otherwise correctly measured. This is why we publish the reference standard used and the acceptance tolerance on every calibration record.

    Do you provide calibration for instruments bought through a distributor?

    Yes. Calibration and repair service is available for instruments purchased through a distributor, not only for direct purchases. Where an instrument has digital output, remote diagnostics can often identify the fault before a unit is returned.

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Model: 7050B  |  Required options: ____________  |  Output protocol: ____________  |  Target delivery: ____________

    Request a Quote

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Your details

    We reply from a named engineer, not a shared inbox.

    First and last name, so we know who we are replying to.

    A company or institutional address. Free mailboxes such as gmail.com are acceptable, but we will not open a reply thread on one.

    Pick a market, or choose the last option to type your own two-letter code.

    This decides who replies and how quickly. A laboratory asking for an accredited method needs a different answer to a reseller asking for a price.

    What you need to measure

    The last two questions decide whether we can quote in one round or two.

    Product families needed *Select every family that applies. One enquiry can cover several.

    What are you measuring, where, and why? Three sentences is enough. Drag and drop the method sheet here if you have one.

    Optional. e.g. NOx, SO2, O2, H2O, particle mass.

    Optional. A range you can already confirm beats a guess. If you only have an approximate value, say so.

    If you are not sure, choose "Not yet determined" — we will ask rather than guess.

    Commercials and delivery

    Optional, but each one removes a round of email.

    Output signals you needSelect all that apply. An instrument that cannot report in your SCADA protocol is not usable, however accurate it is.

    Whole numbers only, or leave blank. For a first enquiry, "1" is an honest answer.

    Optional. A date matters more than a season. If you have a tender deadline, put the real date.

    Optional. Supply voltage, mounting constraints, site conditions, calibration needs.

    We reply within one working day, Monday to Saturday. We do not publish prices on this site.