• en
  • es
  • fr
  • de
  • Request a quote ↗
    kesense. Request a quote

    Ambient Air Quality Monitoring Equipment | kesense

    Environmental Air Monitoring

    Ambient air monitoring serves two purposes that need different instruments. Gravimetric sampling by filter weighing sets the reference a network must be traceable to. Real-time optical measurement gives the temporal resolution and coverage that networks, urban projects and industrial perimeters depend on operationally. Most serious errors come from specifying one and expecting the other.

    What this family covers

    Continuous PM and gas monitors, low-flow and high-volume gravimetric samplers, multi-channel samplers, ozone and DOAS analyzers, automatic noise monitoring with the required statistical descriptors, weather stations, handheld field units and an UAV platform for area survey.

    Applications

    Municipal air quality networks · urban background and traffic stations · industrial perimeter monitoring · construction dust enforcement · indoor air quality · occupational dust exposure · research institutions · airport and port environmental monitoring

    Sub-categories

    How to specify

    Decide first whether the work is regulatory or operational. If a reading will ever be disputed, gravimetric reference data has to exist behind it — the 2031 high-volume sampler is the instrument that provides it. If the work is screening, trending or operational, optical alone may be sufficient and considerably cheaper per point.

    Photography in progress. 1 model(s) in this family are still being photographed and are marked below. They are listed with full specifications so you can quote against them, but the images will follow.

    Models in this family

    Model Product Standards
    2020A Ambient Air Sampler (Electronic Flowmeter) GB 50325-2020 · HJ/T 375-2007 · JJG 956-2013
    2022 Portable Odor Detector GB 14554-93 · HJ 1262-2017 · JJF (R) 115-2023
    2025B Portable PM2.5/PM10 Online Monitoring Instrument WS/T 206-2001 · JJG 846-1993 · JJG 846-2015
    2026 Handheld Gas Detector GB 3836.1-2010 · GB 3836.4-2010 · GB 12358-2006
    2027B Portable Infrared CO/CO2 Analyzer GBZ 2.1-2019 · GBZ/T 300.37-2017 · GB 9801-1988
    2028 Ambient Gas Comprehensive Analyzer GB 3095-2016 · JJG 551-2011 · JJG 635-2011
    2029 UV Gas Analyzer GB 14554-93 · GB/T 37186-2018 · DB 37/T 3786-2019
    2030D Low-Flow TSP / PM10 / PM2.5 Sampler GB/T 38517-2020 · GB/T 39193-2020 · GB/T 16263-2010
    2031 Large Flow Environment Air Particulate Sampler GB/T 39195-2020 · HJ 93-2013 · HJ/T 374-2007
    2036 Environment Air Particulate Sampler HJ 93-2013 · HJ/T 374-2007 · HJ 618-2011
    2050 Integrated Air Comprehensive Sampler GB/T 18883-2022 · GB/T 39193-2020 · GB 50325-2020
    2072 UAV (Four Rotors / Six Rotors) —
    2091 Ozone Analyzer GB/T 18883-2022 · HJ 590-2010 · JJG 1077-2012
    2092 Ambient Air Quality Monitoring Instrument GB 3095-2012 · HJ 653-2013 · HJ 1100-2020
    2193 Environment Noise Automatic Monitoring Instrument GB 3096-2008 · GB/T 3243-2010 · GB/T 3785-2010
    9050B/C Photography required Integrated Automatic Weather Station GB/T 11660-2007 · HJ/T 755-2000 · HJ 194-2017

    Ambient Air Samplers

    2020A · 2030D · 2031 · 2036 · 2050

    Gas Analyzers

    2022 · 2027B · 2028 · 2029 · 2091

    PM2.5 / PM10 Monitors

    2025B · 2026 · 2092

    Mobile Systems

    2072

    Noise & Meteorology

    2193 · 9050B/C

    Frequently asked questions

    Should I specify optical or gravimetric PM measurement?

    Gravimetric filter weighing remains the reference method against which optical instruments are evaluated. Optical monitors give continuous data, a much lower cost per point and the temporal resolution networks need, but they report an equivalent concentration that must be correlated with the reference. If your work is regulatory and defensible you need gravimetric data behind the optical data. If it is operational, optical alone may suffice.

    What data quality indicators matter when comparing monitors?

    Three. Correlation with the reference method against the stated requirement. Agreement of the measurement range with the reference. And data completeness as a percentage of expected samples. A monitor that states these three can be compared objectively; one that publishes only a range figure cannot.

    Can these instruments feed a municipal air quality network?

    The 2092 supports the HJ/T 212-2017 data transmission protocol and is used with HJ 633-2012 AQI calculation and HJ 663-2013 assessment. The 2193 noise monitor also supports HJ 212-2017 and HJ 660-2013. Where your network uses a different protocol, state it in the enquiry — most models can be configured.

    Does a monitoring station need noise measurement as well?

    A station measuring air but not noise will receive complaints it cannot answer, because noise and air quality are assessed together under the environmental quality framework. The 2193 speaks the same HJ 212 protocol as the air monitors, so it fits the same network rather than being a separate system.

    Request a quotation for this family

    Tell us the application, the parameter or gas, the expected measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Application: ____________  |  Parameter / gas: ____________  |  Range: ____________  |  Output protocol: ____________  |  Target delivery: ____________

    Request a Quote  · Standards & Methods reference  · Industry solutions