    Emission Monitoring for Cement, Lime and Steel Plants

    Overview

    Cement, lime and steel plants face a distinctive combination of challenge: extreme flue gas temperatures, high dust loading, sticky or oxidising species that damage sampling lines, and process emissions that vary significantly with production state. The instruments have to survive the duct and produce a result that survives the regulator.

    The compliance picture

    Emissions are assessed against a named method, not against a concentration in isolation. The table below lists the parameters this sector is regulated on, the methods that apply, and what each method actually determines.

    Parameter Method / standard What it determines
    Stack particulate matter GB/T 16157-1996 · HJ/T 48-1999 Isokinetic gravimetric; kilns and sinter plants run continuously
    Process gas composition HJ 1131-2020 · HJ 1132-2020 SO₂ and NOₓ by constant-potential electrolysis
    Flow and velocity determination HJ/T 47-1999 Pitot and thermal methods; velocity under 45 m/s typical
    Dioxins GB 16445-2014 Co-incident with particulate sampling at cement kilns
    Heavy metals HJ 25.3-2019 class Particulate and gas phase sampling for metal content
    Mercury HJ 57-2017 At waste-heat kilns and sinter plants

    Recommended instrument set

    The following combination covers routine compliance testing, screening ahead of a full test, and the reference data a defensible submission needs. Every model is configurable at order — state your range, gas and output protocol and the configuration will be confirmed in the quotation.

    Task Model Key specifications Standards
    Kiln particulate with full gas suite 3012H
    Stack Dust Sampler / Flue Gas Analyzer
    isokinetic sampling, multi-gas, thermal printer HJ/T 48-1999 · JJG 968-2002 · JJG 680-2007
    High-dust low-concentration duty 3012H-D
    and Low-Flow Rate Fixed Source Emission Integrated Tester
    1 mg/m³ lower limit for low-emission configurations GB/T 16157-1996 · HJ/T 47-1999 · HJ/T 48-1999
    High-temperature and aggressive flue gas 3023Y
    UV Flue Gas Analyzer
    UV differential, 24 generations, 1–40 NL/min bypass flow GB/T 37186-2018 · HJ/T 397-2007 · HJ 870-2017
    Continuous monitoring for process control 1089K
    Beta-Ray Stack Dust Sampling Probe
    beta-ray with heated probe and filter GB/T 16157-1996 · HJ/T 397-2007 · DB15/T 2362-2021
    Two-channel gas capture incl. mercury 3072
    Dual-Channel Flue Gas Sampler
    dual independent flow paths GB/T 16157-1996 · HJ/T 47-1999 · HJ/T 397-2007
    Integrative FTIR survey 2086
    Portable Fourier Transform Infrared Gas Analyzer
    12 species, 4.5 cm⁻¹ resolution HJ 819-2017 · HJ 990-2017 · HJ 1013-2018
    On-site flow verification 7020A
    Multi-Range Orifice Flow Calibrator
    0.5 kg, 10–1500 L/min across five ranges HJ/T 368-2007 · HJ 1263-2022 · JJG 640-2016

    Common challenges in this sector

    The problems below come up repeatedly in enquiries from this sector. They are engineering constraints, not sales objections, and the right answer is to specify around them rather than discover them on site.

    Sinter plant flue gas is hot enough to destroy a standard sampling line

    Heat tracing and an extended-temperature probe are not optional here. The 1089A provides configurable heat tracing from 100 to 160 °C with PTFE gas paths rated to 200 °C; specify the heated option explicitly when quoting.

    A kiln test that takes 2–4 hours will not stay isokinetic through a production change

    Test during a steady production state and record the production rate for the period. If the process cannot be held steady, the correct approach is repeated short tests with the data averaged, not one long test — and this decision belongs to your accredited tester, not to the instrument.

    Sticky or oxidising particulate blocks filters and pumps faster than in other sectors

    The visible dust-filter core on the 3012 series is designed for tool-free replacement in the field specifically so a blocked filter does not end a test. Plan filter changes into the test schedule rather than treating them as failures.

    Documents to have ready

    Having the applicable documents in hand before the enquiry shortens the quotation cycle and avoids specifying an instrument against the wrong method. These are the references most frequently requested in this sector.

    • GB/T 16157-1996
    • HJ/T 48-1999
    • HJ 1131-2020
    • GB 16445-2014
    • HJ/T 47-1999

    Request a quotation for this sector

    Tell us the facility type, the parameters you need to measure, your emission limits, the method framework your report must follow and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Sector: Emission Monitoring for Cement, Lime and Steel Plants  |  Facility: ____________  |  Parameters to measure: ____________  |  Applicable method: ____________  |  Target delivery: ____________

    Request a Quote  ·  Standards & Methods reference