Stationary source emission measurement covers the most heavily regulated work in environmental compliance. Kesen builds the instruments that regulatory test bodies and plant environmental teams use to determine particulate matter, gaseous pollutants, flow conditions and moisture in boiler, kiln, furnace and incinerator exhaust.

Key specifications — 3012H

Parameter Specification
Model 3012H
Product type 自动烟尘(气)测试仪
Pitot tube isokinetic sampling, filtering and gravimetric determination Pitot tube isokinetic sampling, filtering and gravimetric determination
Isokinetic tracking with short response time Isokinetic tracking with short response time
Measures stack dynamic pressure, static pressure, atmospheric pressure, flue gas temperature, humidity ratio, flow-meter inlet pressure and temperature, O2, SO2, CO, NO, NO2, H2S, CO2, and isokinetic sampling velocity Measures stack dynamic pressure, static pressure, atmospheric pressure, flue gas temperature, humidity ratio, flow-meter inlet pressure and temperature, O2, SO2, CO, NO, NO2, H2S, CO2, and isokinetic sampling velocity
High-load low-noise sampling pump High-load low-noise sampling pump
High-capacity data storage with USB export and Windows-based database and communication system High-capacity data storage with USB export and Windows-based database and communication system
Intelligent software calibration Intelligent software calibration
Automatic software cross-interference compensation among flue gas components Automatic software cross-interference compensation among flue gas components
Automatic fault self-diagnosis Automatic fault self-diagnosis
Dust suck-back protection Dust suck-back protection
Visible dust-filter core, tool-free replacement, protects gas path and pump Visible dust-filter core, tool-free replacement, protects gas path and pump
High-efficiency gas-water separator extending silastic service life High-efficiency gas-water separator extending silastic service life
Wide-temperature large-screen LCD Wide-temperature large-screen LCD
Dust-proof and water-proof keyboard Dust-proof and water-proof keyboard
High-speed miniature thermal printer High-speed miniature thermal printer
Optional flue gas processor, low-concentration multi-function probe, pitch smoke probe, oil smoke probe

Standards

HJ/T 48-1999 · JJG 968-2002 · JJG 680-2007

Applications

Thermal power and biomass plants · cement, lime and steel kilns · waste incineration and solid waste treatment · chemical process heaters · industrial furnaces · sulfuric acid plants · gas turbines and fuel gas exhaust

Configuration

Configuration options: flue gas processor · low-concentration sampling probe · pitch smoke probe · oil smoke probe · high-capacity data storage with USB export · Windows-based database and communication system

Frequently asked questions

Which method framework applies to my stack test?

The instrument must suit the framework your report is prepared under. Our stack samplers are built to GB/T 16157-1996 and HJ/T 48-1999 for isokinetic gravimetric particulate determination, with a low-concentration gravimetric method to a stated lower testing limit of 1 mg/m³. The physical principle, probe geometry and gravimetric determination are the same as US EPA Method 1-5 and EN 13264-1; procedural details for flow verification, leak checks and calculation differ between frameworks. We supply the instrument configuration and verification records your accredited test body requires — the compliance report is prepared by your own tester.

Can I configure the instrument for my stack geometry?

Yes. Sampling probe type and length, pitot configuration, flue gas processor, low-concentration probe, gas configuration, pump flow rate, output protocol, data storage and power input are specified at order. Note that modifications to a performance-tested instrument can affect its suitability status in jurisdictions where a formal assessment is required, and we flag this wherever it applies.

What accuracy should I expect, and how is it stated?

Every specification we publish carries its measurement conditions — range, ambient temperature, compensation mode, gas and response time. We do not publish a bare accuracy figure without the context that makes it meaningful. If a competitor's datasheet omits those conditions, ask both of us for the same test and compare.

Request a quotation

Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

Model: 3012H  |  Required options: ____________  |  Output protocol: ____________  |  Target delivery: ____________

Request a Quote