    Stationary source emission measurement covers the most heavily regulated work in environmental compliance. kesense builds the instruments that regulatory test bodies and plant environmental teams use to determine particulate matter, gaseous pollutants, flow conditions and moisture in boiler, kiln, furnace and incinerator exhaust.

    Key specifications — 1089K

    Parameter Specification
    Model 1089K
    Product type Beta-Ray Stack Dust Sampling Probe
    Concentration range Concentration (0~50) mg/m3
    Probe heating temperature Probe heated 130C (100~160 optional)
    Filter temperature Filter 105C
    Flow rate Flow 33 L/min
    Stack gas temperature Stack temp (0~500)C
    Duct size Duct >=60 mm
    Specification Standard-membrane calibration
    Power consumption <150 W

    Measurement conditions

    • Reference temperature — 25 °C ambient unless a row states otherwise
    • Reference pressure — 101.3 kPa
    • Humidity — non-condensing
    • Response time — T90 as stated per configuration

    Range, compensation mode, gas and response time are confirmed per configuration at order. Every figure above is tied to its stated condition — ask us for the exact reference behind any number.

    Standards

    GB/T 16157-1996 · HJ/T 397-2007 · DB15/T 2362-2021 · DB21/T 3270-2020 · DB22/T 3426-2023 · DB36/T 1386-2021 · DB37/T 3785-2019 · DB42/T 1954-2022 · DB63/T 1873-2020

    Applications

    Thermal power and biomass plants · cement, lime and steel kilns · waste incineration and solid waste treatment · chemical process heaters · industrial furnaces · sulfuric acid plants · gas turbines and fuel gas exhaust

    Configuration

    Measurement range, sampling flow, probe type, gas configuration, output protocol and data storage are specified at order. State your requirement and we will confirm the configuration in the quotation.

    Frequently asked questions

    Which method framework applies to my stack test?

    The instrument must suit the framework your report is prepared under. Our stack samplers are built to GB/T 16157-1996 and HJ/T 48-1999 for isokinetic gravimetric particulate determination, with a low-concentration gravimetric method to a stated lower testing limit of 1 mg/m³. The physical principle, probe geometry and gravimetric determination are the same as US EPA Method 1-5 and EN 13264-1; procedural details for flow verification, leak checks and calculation differ between frameworks. We supply the instrument configuration and verification records your accredited test body requires — the compliance report is prepared by your own tester.

    Can I configure the instrument for my stack geometry?

    Yes. Sampling probe type and length, pitot configuration, flue gas processor, low-concentration probe, gas configuration, pump flow rate, output protocol, data storage and power input are specified at order. Note that modifications to a performance-tested instrument can affect its suitability status in jurisdictions where a formal assessment is required, and we flag this wherever it applies.

    What accuracy should I expect, and how is it stated?

    Every specification we publish carries its measurement conditions — range, ambient temperature, compensation mode, gas and response time. We do not publish a bare accuracy figure without the context that makes it meaningful. If a competitor's datasheet omits those conditions, ask both of us for the same test and compare.

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Model: 1089K  |  Required options: ____________  |  Output protocol: ____________  |  Target delivery: ____________

    Request a Quote

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Your details

    We reply from a named engineer, not a shared inbox.

    First and last name, so we know who we are replying to.

    A company or institutional address. Free mailboxes such as gmail.com are acceptable, but we will not open a reply thread on one.

    Pick a market, or choose the last option to type your own two-letter code.

    This decides who replies and how quickly. A laboratory asking for an accredited method needs a different answer to a reseller asking for a price.

    What you need to measure

    The last two questions decide whether we can quote in one round or two.

    Product families needed *Select every family that applies. One enquiry can cover several.

    What are you measuring, where, and why? Three sentences is enough. Drag and drop the method sheet here if you have one.

    Optional. e.g. NOx, SO2, O2, H2O, particle mass.

    Optional. A range you can already confirm beats a guess. If you only have an approximate value, say so.

    If you are not sure, choose "Not yet determined" — we will ask rather than guess.

    Commercials and delivery

    Optional, but each one removes a round of email.

    Output signals you needSelect all that apply. An instrument that cannot report in your SCADA protocol is not usable, however accurate it is.

    Whole numbers only, or leave blank. For a first enquiry, "1" is an honest answer.

    Optional. A date matters more than a season. If you have a tender deadline, put the real date.

    Optional. Supply voltage, mounting constraints, site conditions, calibration needs.

    We reply within one working day, Monday to Saturday. We do not publish prices on this site.