Sampling Probes and Accessories

The probe determines the quality of everything downstream. A sampler configured with the wrong probe type, the wrong temperature rating or a worn filter holder produces a technically correct but methodically invalid result — and the bias may not be detectable in the calculation that follows.

What this family covers

Gas pre-treatment systems combining heating, filtration and water removal, capacity-method moisture detectors, oil fume extraction probes rated for heated industrial stacks, multifunction sampling probes with configurable heat tracing, condensing probes, and filter membrane equipment for automatic sampling.

Applications

Stack sampling trains · gas conditioning and moisture removal · oil fume extraction · high-temperature flue gas applications · absorber bottle configurations · filter-based automatic sampling

Sub-categories

How to specify

Probe specification is where the cost of a wrong decision concentrates. State the flue gas temperature, the duct diameter and the method you must follow, and the probe will be specified to match — including whether you need heat tracing and to what temperature.

Photography in progress. 8 model(s) in this family are still being photographed and are marked below. They are listed with full specifications so you can quote against them, but the images will follow.

Models in this family

Model Product Standards
1030 Photography required Gas Analysis Preprocessing System GB/T 16157-1996
1032 Photography required Gas Analysis Preprocessing System GB/T 16157-1996
1062C Photography required Moisture Content Detector with Capacity Method GB/T 16157-1996 · T/SSESB 1-2000
1062E Photography required Moisture Content Multi-Function Detector GB/T 16157-1996 · HJ 836-2017 · T/SSESB 1-2000
1087A Photography required Oil Fume Extraction Probe GB 18483-2001 · HJ/T 107-2019
1089A Photography required Exhaust Gas Intake Multifunctional Sampling Probe GB/T 16157-1996 · HJ 67-2001 · HJ 544-2016
1089T Photography required Multifunctional Condensing Gas Inlet Sampling Probe GB/T 16157-1996 · HJ/T 476-2018
9020A Photography required Automatic Membrane Pump —

Sample Conditioning

1030 · 1032

Sampling Probes

1062C · 1062E · 1087A · 1089A · 1089T · 9020A

Frequently asked questions

Why does probe selection matter so much?

Because the probe sits in the gas stream and defines what the rest of the system measures. Probe diameter, material and temperature rating must match the duct geometry and the flue gas temperature. A leak in the probe or a degraded filter holder biases the entire result, and the bias may not be detectable in the subsequent gravimetric calculation.

What temperature can these probes handle?

The 1089A and 1089T use heated sampling lines rated to 200 °C with configurable heat tracing. The 1087A oil fume probe is rated to 200 °C with an extraction efficiency of at least 95%. Higher-temperature applications require the extended-temperature options; specify your working temperature and we will confirm the configuration.

What does the pre-treatment system actually remove?

The 1030 and 1032 combine heating, filtration and water removal, with outlet dew point down to 4–5 °C. This protects the analyser from particulate, condensation and water load, all three of which bias a gas measurement and are the most common cause of an analyser failing to reach its specified accuracy in the field.

How often should consumable parts be replaced?

It depends on the duty cycle and the gas being sampled, so rather than publishing a single number we publish the part numbers and typical service life per product family and ask you to set the interval from your own usage data. Ask your sales representative for the consumables list for your specific model.

Request a quotation for this family

Tell us the application, the parameter or gas, the expected measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

Application: ____________  |  Parameter / gas: ____________  |  Range: ____________  |  Output protocol: ____________  |  Target delivery: ____________

Request a Quote  · Standards & Methods reference  · Industry solutions