• en
  • es
  • fr
  • de
  • Request a quote ↗
    kesense. Request a quote
    7004

    Transmission Smoke Meter

    Request a Quote
    Every specification carries its measurement conditions — range, ambient temperature, compensation mode, gas and response time. We do not publish a bare accuracy figure without the context that makes it meaningful.
    7004

    Overview

    Fuel vapour recovery testing and vehicle emission testing are two established test regimes with fixed numeric acceptance limits. Both require equipment that reproduces the specified measurement faithfully under field conditions. kesense supplies the instruments for all of them, built to the applicable national emission and fuel quality standards.

    Key specifications — 7004

    Parameter Specification
    Model 7004
    Product type Transmission Smoke Meter
    Opacity Opacity Ns (0~99.0)%
    Extinction coefficient Extinction coefficient k (0~16.08) m-1
    Operating temperature Temperature (0~150)C or (-40~130)C
    Drift Ns drift <=+/-0.30%/min
    Repeatability Repeatability 1.0%
    Response time Response (1.0+/-0.1) s
    Optical path Optical path 0.215 m
    Sampling Sampling tube 3 m
    Weight ~7.0 kg
    Power consumption <80 W
    Battery life Internal Li-ion >=6 h

    Measurement conditions

    • Reference temperature — 25 °C ambient unless a row states otherwise
    • Reference pressure — 101.3 kPa
    • Humidity — non-condensing
    • Response time — T90 as stated per configuration

    Range, compensation mode, gas and response time are confirmed per configuration at order. Every figure above is tied to its stated condition — ask us for the exact reference behind any number.

    Standards

    GB 3847-2018 · GB 36886-2018 · JJF 1482-2014 · JJG 976-2024

    Applications

    Petrol station vapour recovery compliance · tanker vapour balance testing · vehicle exhaust opacity testing · fuel terminal and depot monitoring · environmental inspection · LDAR at fuel storage and distribution sites

    Configuration

    Measurement range, sampling flow, probe type, gas configuration, output protocol and data storage are specified at order. State your requirement and we will confirm the configuration in the quotation.

    Frequently asked questions

    What tests does the oil vapour recovery tester perform?

    Three, and they share one instrument. The tightness test pressurises the vapour recovery system with nitrogen to a specified level and compares the residual pressure after a set holding time against the minimum allowable limit. The liquid resistance test passes nitrogen at three specified flow rates and requires the pressure differential to stay below the limit at each. The gas-liquid ratio test compares collected vapour volume against dispensed fuel volume and requires the ratio to fall within the specified band. Our 7003 performs all three.

    What acceptance limits apply to oil vapour recovery testing?

    Under GB 20952-2020 and related regulations: nitrogen at 18, 28 and 38 L/min must not exceed pressure differentials of 40, 90 and 155 Pa respectively. The gas-liquid ratio must fall between 1.0 and 1.2. Treatment device emission concentration must not exceed 25 g/m³ as a one-hour average. Leak detection must not exceed 500 μmol/mol. Fence-line non-methane total hydrocarbon must not exceed 4.0 mg/m³ as a one-hour average. Equipment calibration pressure gauges must be calibrated at intervals not exceeding 90 days.

    Which standards do the vapour recovery and smoke meter models meet?

    The 7003 meets GB 20952-2020 for petrol station vapour recovery. The 7005 meets GB 20951-2020 for tanker transport. The 7004 transmission smoke meter meets GB 3847-2018 for diesel vehicles and GB 36886-2018 for petrol vehicles, with verification per JJG 976-2024.

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Model: 7004  |  Required options: ____________  |  Output protocol: ____________  |  Target delivery: ____________

    Request a Quote

    Request a quotation

    Send the application, the parameter or gas, the measurement range, the output protocol required and your target delivery date. An engineer will reply with a configuration recommendation and a price — normally within one working day.

    Your details

    We reply from a named engineer, not a shared inbox.

    First and last name, so we know who we are replying to.

    A company or institutional address. Free mailboxes such as gmail.com are acceptable, but we will not open a reply thread on one.

    Pick a market, or choose the last option to type your own two-letter code.

    This decides who replies and how quickly. A laboratory asking for an accredited method needs a different answer to a reseller asking for a price.

    What you need to measure

    The last two questions decide whether we can quote in one round or two.

    Product families needed *Select every family that applies. One enquiry can cover several.

    What are you measuring, where, and why? Three sentences is enough. Drag and drop the method sheet here if you have one.

    Optional. e.g. NOx, SO2, O2, H2O, particle mass.

    Optional. A range you can already confirm beats a guess. If you only have an approximate value, say so.

    If you are not sure, choose "Not yet determined" — we will ask rather than guess.

    Commercials and delivery

    Optional, but each one removes a round of email.

    Output signals you needSelect all that apply. An instrument that cannot report in your SCADA protocol is not usable, however accurate it is.

    Whole numbers only, or leave blank. For a first enquiry, "1" is an honest answer.

    Optional. A date matters more than a season. If you have a tender deadline, put the real date.

    Optional. Supply voltage, mounting constraints, site conditions, calibration needs.

    We reply within one working day, Monday to Saturday. We do not publish prices on this site.